HP OpenVMS Systemsask the wizard |
The Question is: Is UCX limited in the number of connections? If not how can I increase the number of concurrent connection? If it is a SYSGEN parameter which one(s)? After approximatly 60 successful remote telnet terminal emulation logins, additional remote login attempts are not greeted with usual username: request. At this point, if I have the user switch protocol to LAT or DECnet he/she can login no problem. My goal is to have a pure TCP/IP network and standardize and simplify my desktop configurations. I know a solution exist please help. Note: if the answer is in the UCX documentaion I can not find it! I am currently running OpenVMS V7.1-1H1 and UCX V4.1-12 with UCXECO_41_2 V2.0. Thanks, John The Answer is : SET LOGINS/INTERACTIVE is one obvious limit, the number of processes permitted by MAXPROCESSCNT is another, as are the TCP/IP Services for OpenVMS (UCX) communication services limits set by the UCX command SET COMMUNICATION /SERVICES.
|