The Question is:

 
ACCVIO at decw$endsession.
 
we use excursion V7 on WinNT. From VMS machine
we create display using
 
$ set display/create/node=<IP Address of NT>/transport=tcpip
 
And then give run sys$system:decw$session
and use the terminal on NT machine.
 
When we give end session from Terminal we get
System fatal access violation message on VMS machine.
The failing module is decw$endsession.
 
 


The Answer is :

 
  Please apply the available ECO kit for whichever version of DECwindows is
  in use -- V1.2-3, V1.2-4, and V1.2-5 are common DECwindows versions.
 
  Also check for and apply available ECO kits for the particular TCP/IP
  Services version, or the ECO kit(s) for the particular IP product in use.
 
  Also check for and apply the current C ECO kit.
 
  If the problem persists, please contact the Compaq Customer Support
  Center for assistance.