Cause of XQP Bugcheck?

» close window

The Question is:

 
 
 
Dear Wizzard,
 
My question is about a MicroVax 3800, our system crash over the weekend, we have the dump file that was produced before it crash. The file has the following error on it XQPERR, Error detected by file system XQP. The Microvax is connected to Storageworks c
abinet using a controller which is a MTI Qbus to SCSI controller that emulates a KDA controller. Our question is. Does this machine need a patch needed, or is there something else that could be wrong with it.
 
Thanks,
 
David Cousins
 


The Answer is :

 
  The OpenVMS Wizard has no idea what the particular trigger for
  this crash is -- it could be hardware, software, or otherwise.
 
  There are various ECO kits available for OpenVMS VAX V5.5-2,
  but without some idea of what happened it is difficult to
  determine of this is a known problem.  Please apply the various
  mandatory ECO kits as a start, and please check the error log
  and the device error counts for anything unusual.
 
  If the problem persists, please contact the Compaq Customer
  Support Center for further assistance.

answer written or last revised on ( 2-MAR-2000 )