EDIT (Editor) NONANSICRT Error?

» close window

The Question is:

 
I have created a new alpha account however I am unable to create a new file
 using the EDIT command. The error message I get is
 
%TPU-E-NONANSICRT, SYS$INPUT must be supported CRT
 
Can you help??
 
Thanks..
 
Ash
 


The Answer is :

 
  Please add SET TERMINAL/INQUIRE to the LOGIN.COM or SYLOGIN.COM.
  (This command will typically be able to automatically set up the
  terminal attributes for the specific terminal in use.)
 
  For details and suggestions, please see SYS$STARTUP:SYLOGIN.TEMPLATE.
 
  The following text will be updated to reflect SET TERMINAL/INQUIRE:
 
	--
 
$ HELP/MESSAGE NONANSICRT
 
 NONANSICRT,  SYS$INPUT must be supported CRT
 
  Facility:     TPU, DEC Text Processing Utility (DECTPU)
 
  Explanation:  DECTPU was run with SYS$INPUT associated with a terminal that
                does not have the appropriate characteristics, or DECTPU was
                run from a command procedure without assigning SYS$INPUT to
                SYS$COMMAND.
 
  User Action:  Run DECTPU from a supported device or use the /NODISPLAY
                command qualifier. In a command procedure, assign SYS$INPUT
                to SYS$COMMAND before invoking DECTPU.
 
 