MicroVAX 3100 UNXINT, RT-retrbtcr error?

» close window

The Question is:

 
dear sir,
 
       We have Vax 3100-80 system
       When system is doing its slef test,
       i am getting messages like this, after
       that system not booting and hangs,
 
       ?33 UNXINT
           010 E0040000 041F0000
       ??RT Retrbtcr 041F0000
 
       Situation is critical
       Pl , respond immediatly.
 
 


The Answer is :

 
  Your MicroVAX 3100 model 80 system appears to have a hardware problem,
  probably involving either the processor module or the memory.
 
  Please contact your hardware service organization for assistance.
 
  For time-critical issues, please contact the Compaq Customer Support
  Center directly.
 

answer written or last revised on ( 16-OCT-2001 )