[an error occurred while processing this directive]

HP OpenVMS Systems

ask the wizard
Content starts here

SET SECURITY parsing error?

» close window

The Question is:

 
I am not able to change the device protection of any magnetic tape station
 according to the System Manager Essentials Manual, page 7-6 with
e.g. SET SEC/CLASS=DEVICE $2$MKC500: /PROT=W:RWC
on the SYSTEM account with full privileges.
All I get is a
%SET-F-SYNTAX, error parsing 'W:RWC'
-LIB-F-SYNTAXERR, string syntax error detected by LIB$TPARSE.
 
VMS Cluster with two nodes running OpenVMS V7.1-2
 


The Answer is :

 
  Thank you for reporting this error -- this has been replicated
  with current documentation and with OpenVMS Alpha V7.3-1.
 
  In the interim, please use:
 
    SET SECURITY/CLASS=DEVICE $2$mkc500: /PROTECTION=(W:RW)
 
  Experimentation indicates the request for control access is the
  trigger for the parsing error.
 

answer written or last revised on ( 13-JAN-2003 )

» close window