dismissing i/o device interrupt?

» close window

The Question is:

 
OpenVMS v7.3-2. After upgrading a GS160
from v7.3-1 to v7.3-2 receive the following
error right after entering b at the console
boot prompt (> b)
 
dismissing i/o device interrupt number xxxx,
not delivered to CPU 9
 
xxxx = a four-digit integer whose value
changes at each boot.
 
Thanks in advance.
 


The Answer is :

 
  Please ensure you have current SRM firmware loaded, and please
  then contact your hardware service organization or HP services
  for assistance -- the usual causes of this error message result
  from a system crash and are effectively harmless; the message
  is informational.
 
  Message sequences such as the following:
 
**** OpenVMS (TM) Alpha Operating System V7.3-1   - BUGCHECK ****
dismissing I/O Device Interrupt Number 68, not delivered to CPU 1
dismissing I/O Device Interrupt Number 164, not delivered to CPU 5
dismissing I/O Device Interrupt Number 130, not delivered to CPU 7
...
 
  Indicate that interrupts targetting specific processors are being
  cleaned up after a crash.
 