[an error occurred while processing this directive]

HP OpenVMS Systems Documentation

Content starts here
HP Pay per use (PPU) User's Guide for versions 8.x > Chapter 3 Installing and Configuring PPU Software

Installing PPU Software

 » Table of Contents

 » Index

If you currently have PPU software installed that is older than version B.05.00 (for example, version B.04.01), contact your HP sales representative to find out how to update to PPU 8.x software.

Find the Latest Patches (HP-UX)

This document lists the patches required to install and run PPU 8.x software known at the time of publication. To find the most current patches, go to the HP Software Depot at http://www.hp.com/go/softwaredepot and perform the following steps:

  1. Enter the PPU software product T2351AA into the search text box then click the search button.

  2. Click the Pay per use Agent Software link that appears as a result of your search.

  3. Click the installation link, near the bottom of the page.

The required patches for PPU 8.x are listed. You can then retrieve the necessary patches from the HP web site: http://itrc.hp.com

Installing from the HP-UX Media (HP-UX)

Follow this procedure to install the PPU 8.x software on your HP-UX 11i v1 or 11i v2 system from either the Operating Environment or Applications Software media:

  1. Log in as root.

  2. Determine the drive device file by entering the following command:
     
    ioscan -fnC disk

  3. Insert the Operating Environment or Applications Software media into the drive.

  4. Mount the drive to the desired directory. The following example uses the /dev/dsk/c1t2d0 device file (from Step 2) and the /cdrom directory. To mount the drive, enter a similar command as:
     
    mount -r /dev/dsk/c1t2d0 /cdrom

  5. Install the PPU 8.x bundle T2351AA from the media:
     
    swinstall -s /cdrom T2351AA

  6. Continue with “Configuring PPU Software ”.

Installing from the HP Software Depot (HP-UX)

  1. Do a search for the PPU product T2351AA at the HP Software Depot web site: http://www.hp.com/go/softwaredepot

  2. Click the Pay per use Agent Software link that appears as a result of your search

  3. Read the “overview” page, then click the installation link (at the bottom of the page).

  4. Read the “installation” page, then click the receive for free button.

  5. Fill in the registration information, click the appropriate operating system link, and then click the Next button.

  6. Click the appropriate link, under the “download software” table title, and download the depot file to the following directory: /var/tmp

    You can rename the download but the filename is a name similar to these:
    /var/tmp/T2351AA_B.08.00.01.05_HP-UX_B.11.23_IA+PA.depot
    /var/tmp/T2351AA_B.08.00.01.05_HP-UX_B.11.11_32+64.depot

  7. On the PPU system, log in as root.

  8. Install the appropriate PPU bundle (11i v2 example):
     
    swinstall -s \ /var/tmp/T2351AA_B.08.00_HP-UX_B.11.23.IA+PA.depot ’*’

    You can also use the interactive swinstall to install the depot file by setting the target to /var/tmp/<package_name>. The PPU 8.x software is a low-overhead and non-intrusive software module. The file-system size increases by approximately 5MB and a reboot is not required.

  9. Continue with “Configuring PPU Software ”.

Installing on Windows Server 2003 Systems

Before installing the PPU software, ensure that all drivers, utilities, and security updates for your system available on the Smart Setup and Smart Update media have been installed. In particular, the Smart Components containing the prerequisite products HP WMI nParProvider, HP WMI Mapper, and HP Baseboard Management Controller Driver (the Driver is automatically installed by the Support Pack) should already have been installed.

NOTE: Do not install the PPU software on a remote management station. You must install this software on a hard partition of the HP Integrity server running the Windows Server 2003 (Enterprise or Datacenter Edition) 64-bit operating system.

To install the PPU software on each hard partition running Windows Server 2003:

  1. Log onto the first Windows partition of the target server as Administrator (use the administrative logon and password, or use an account with Administrator privileges).

  2. Browse the Smart Setup CD or the http://www.hp.com/support/itaniumservers website for your appropriate server type and then navigate to the Pay per use (PPU) package. The title of the Smart Component is hp CPU PayPerUse Agent for Windows Server 2003 64-bit Edition.

  3. When the component is displayed, click Download and choose Run.

  4. Ensure that you have the latest version of the PPU installer, cp006445.exe.

  5. In the HP Package Setup screen, you can choose Extract or Install. Choose Install to complete the installation with minimal prompting for a “typical” installation. Choose Extract if you wish more control over the installation options; in the case of PPU, the only significant installation option is whether or not PPU should be installed in a directory other than the default location.

  6. In all cases, you will be prompted to accept a license agreement during the installation.

  7. When the installation is complete, reboot the partition if you are prompted to do so - or if you previously deferred a reboot after the installation of the WMI nPartition Provider. (If the installation fails or the PPU service fails to start, you should definitely reboot and try reinstalling PPU.)

  8. The installation also updates the system PATH, so if you do not reboot after the installation, you should close and reopen any command prompt windows that you plan to use for configuration and management of PPU.

Additional Windows Installation Considerations

The packaging and installation of Pay per use changed between the initial version 7.01 and version 7.1. In 7.01, Pay per use was included with the WMI nPar Provider component, and only visible as a subcomponent of the WMI nPar Provider. Do not mix installation modes between the old and the new methods (PPU as a subcomponent or nPar or PPU as a separate entity). After a successful PPU installation, PPU is listed separately under Add or Remove Programs. Do not attempt to reinstall PPU by modifying the WMI nPar Provider package.

Upgrading the WMI nPar Provider or WMI Mapper may cause the PPU service to stop running. After upgrading the WMI nPar Provider or WMI Mapper, reboot or check the status of the HP Pay Per Use service in the Windows Services applet to make sure the service is still running.

NOTE: When the WMI Mapper is upgraded from Smart Setup version 4.5 or later, you must also reinstall the PPU agent from Smart Setup version 4.5 or later. Without the reinstallation of PPU, the PPU service will fail to start properly.

If the installation fails, or the PPU service fails to start, it may be because of a deferred but necessary reboot after installing the WMI nPar Provider. Try rebooting, and if necessary, reinstalling PPU.

Installing from the OpenVMS I64 OE DVD

Follow this procedure to install the PPU V8.x software on your OpenVMS V8.3 system. The PPU product kit is located on the OpenVMS I64 OE DVD.

  1. Log into a privileged system account.

  2. Insert the OpenVMS I64 OE DVD into a DVD-R device accessible to the partition where you intend to install the software.

  3. Mount the DVD drive with the DCL MOUNT command as below:
     
    $ mount DQA0:I64083 I64083
    %MOUNT-I-WRITELOCK, volume is write locked
    %MOUNT-I-MOUNTED, I64083 mounted on _DQA0: (NODE)

  4. Set your default working directory or define the logical PCSI$SOURCE to the directory on the DVD where the PPU kit resides. You may use the two directory locations below in either of the DCL commands:

    $ DEFINE PSCI$SOURCE DQA0:[PPU_I64080.KIT}

    or

    $ SET DEFAULT DQA0:[KITS.PPU_I64080]

    The PSCI kit file, HP-I64VMS-PPU-V0800--1.PSCI, will be located in the kit directory.

  5. Install the PPU V8.x kit from the media with the DCL command:

    $ PRODUCT INSTALL PPU

    You will see output similar to below when installing the kit:

    Performing product kit validation ...
    %PSCI-I-VALPASSED, validation of $DQA0:[000000]HP-I64VMS-PPU-V0800--1.PSCI$COMPRESSED;1 succeeded

    The following product has been selected:
      HP I64VMS PPU V8.0        Layered Product

    Do you want to continue? [YES]

    Configuration phase starting ...

    You will be asked to choose options, if any, for each selected product and for any products that may be installed to satisfy software dependency requirements.

    HP I64VMS PPU V8.0

    * This product does not have any configuration options.

    Execution phase starting ...

    The following product will be installed to destination:
      HP I64VMS PPU V8.0        DISK$SYSDEVICE:[VMS$COMMON.]

    Portion done: 0%...50%...90%...100%

    The following product has been installed:
      HP I64VMS PPU V8.0        Layered Product
    $

  6. Execute the OpenVMS PPU configuration utility to verify your software environment and register the WBEM providers required by PPU.

    $ @sys$manager:ppu$config.com
          hp OpenVMS Industry Standard 64
        Pay Per Use (PPU) configuration utility

    Are you ready to start the configuration process? (Y/N): Y

    Starting configuration of the nPar provider:
    Starting configuration of the iCAP provider:
    Verifying providers status...
    providers OK!...
    Registering PPU Command Language Definition file...
    Command Language Definition file successfully registered
    %DCL-I-SUPERSEDE, previous value of PPU$ROOT has been superseded

    Please add the following lines to your STARTUP procedure:

    $ DEFINE/SYS/EXEC/TRANS=CONCEAL PPU$ROOT ‘F$TRNLNM("SYS$SPECIFIC")
    $ @SYS$STARTUP:PPU$STARTUP

    ***********************************************************
    * Congratulations!                                        *
    *                                                         *
    * PPU has been successfully configured                    *
    *                                                         *
    * Warning: Do not attempt to start the PPU software       *
    * before setting up the address of the utility meter with *
    *                                                         *
    *  ppu config/meter_address                               *
    *                                                         *
    ***********************************************************

  7. Add the PPU startup and PPU shutdown procedures to your site specific startup and shutdown procedures.

    As instructed by the installation, add the following two lines to your startup procedure, SYS$MANAGER:SYSTARTUP_VMS.COM:

    $ DEFINE/SYS/EXEC/TRANS=CONCEAL PPU$ROOT ’F$TRNLNM("SYS$SPECIFIC")
    $ @SYS$STARTUP:PPU$STARTUP



    Note: You may define the PPU$ROOT logical to a device and directory of your choosing. The root does not have to reside on the system device.

    Add the line below to your site specific shutdown procedure, SYS$MANAGER:SYSHUTDWN.COM:

    $ @SYS$MANAGER:PPU$SHUTDWN

  8. Continue with “Configuring PPU Software ”.